THE DESIGN OF RADIOLOGY VIEWING BOX USING POTENTIOMETER SYSTEM
Keywords:
Viewing box, PotentiometerAbstract
Background: In the process of work to gain the maximum results, a radiologist needs a viewing box tool to read radiographs. Aims: to create a viewing box tool by using a potentiometer system.
Methods: This study used applied research method by creating and using the design of viewing ox tool by using a potentiometer system and testing the viewing box tool created by using a Lux meter and 15 respondents consisting of five radiologists and 10 radiographers who should fulfill the questionnaire form.
Results: The mean of viewing box illumination reached 220 lux. The results of the questionnaire showed that 100% radiologist gave an A (excellent) and expressed that the viewing box tool created could be used properly and 90% radiographers provided an A (excellent) and expressed that the viewing box tool created could be used properly, while 10% radiographer gave a value of
B (moderate).
Conclusion: viewing box tool created could be used properly and obtained optimal results as a tool in reading radiographs. Potentiometer system contained in the viewing box was very helpful in reading radiographs because it allowed to adjust the light intensity according to user needs.
Downloads
References
T Nyathi, MSc, AN Mwale, BSc, P Segone, BMedSc, SH Mhlanga, BSc, and ML Pule, BmedSc. Radiographic viewing condition at Johannesburg Hospital. Biomed Imaging Interv J. 2008 Apr-Jun; 4(2):e17
Jenkins, David. Radiographic Photography and Imaging Processes. Roctville: Maryland 20850. 1980
Alter AJ, Kargas GA, Kargas SA, et al. The influence of ambient and viewbox light upon visual detection of low-contrast targets
in a radiograph. Invest Radiol. 1982;17(4):402–6.
Chasney,D.N.Radiographic Imaging. Blackwell Scientific Publications: Oxford. 1989
McCarthy E1, Brennan PC. Viewing conditions for diagnostic images in three major Dublin hospitals: a comparison with WHO
and CEC recommendations. Br J Radiol. 2003 Feb;76(902):94-7
Kimme-Smith C1, Haus AG, DeBruhl N, Bassett LW. Effects of ambient light and view box luminance on the detection of
calcifications in mammography. AJR Am J Roentgenol. 1997 Mar;168(3):775-8.
The Authoritative Dictionary of IEEE Standards Terms (IEEE 100) (edisi ketujuh ed.). Piscataway, New Jersey: IEEE Press.
ISBN 0-7381-2601-2.
Kepmenkes. Pedoman Kendali Mutu (Quality Control) Peralatan Radiodiagnostik. Keputusan Menteri Kesehatan Republik
Indonesia Nomor 1250/MENKES/SK/XII/2009: Jakarta. 2009
Downloads
Published
Issue
Section
License
Copyright (c) 2022 Each author(s) agree to transfer all copyrights and assign YAYASAN ALIANSI CENDEKIAWAN INDONESIA THAILAND, the Publisher of Proceedings of the International Conference on Applied Science and Health, for the full term of exclusive copyright and any extensions or renewals of that terms thereof throughout the world, including but not limited to publish, disseminate, transmit, store, translate, distribute, sell, republish and use the Contribution and material contained therein in print and electronic form of the journal and in other derivative works, in all languages and any form of media of expression available now or in the future and to license or permit others to do so.
This work is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License.
Proceedings of the International Conference on Applied Science and Health is an open access following Creative Commons License Deed – Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0). Users are allowed to copy and redistribute the material in any medium or format as well as remix, transform, and build upon the material with one condition--appropriate credit is given to the journal.